OAKWORKS® 300 Series Procedure ChairUSER MANUALwww.oakworksmed.com · 717.235.6807made in the USAwith US & imported parts
DIRECTIONS FOR USEThe chair can be easily rotated without a patient in it. This is the preferred method. To rotate the chair with an average size pati
DIRECTIONS FOR USE8CAUTIONHEAD REST USEDo not extend the dowels more than 4” (10 cm.) from the Back Rest section.Adjustable LargeThe Adjustable head r
Slide out the Procedure Tray by pulling on the center slot of the tray holder until the tray stops. After a procedure is performed, remove the Procedu
10DIRECTIONS FOR USETo load the paper, locate the two paper holder support arms located on the underside of back rest.Insert rod through paper roll an
11DIRECTIONS FOR USEPROCEDURE CHAIR FACE REST CRESCENTThe Procedure Chair Face Rest Crescent is designed to be used for prone positioning. An Adjustab
12CLEANING & DISINFECTION / INSPECTIONS / WARRANTYCLEANING & DISINFECTIONBefore cleaning with any liquid cleaner be sure to unplug the power c
13MODEL NUMBER & SERIAL NUMBERMODEL & SERIAL NUMBERSMODEL NUMBER DESCRIPTIONPC30 G3XXXXXX3MTT XXXXProcedure ChairBase:30 = Standard BaseSW =
14SPECIFICATIONSPRODUCT SPECIFICATIONSWeight 280-325 lbs. (127-148 kg.)Shipping Weight 372-417 lbs. (169-189 kg.)Lifting Capacity 550 lbs. (250 kg.)EN
15SPECIFICATIONSGuidance and manufacturer’s declaration - electromagnetic emissionsThe chair is intended for use in the electromagnetic environment sp
16SPECIFICATIONSGuidance and manufacturer’s declaration - electromagnetic immunityThe chair is intended for use in the electromagnetic environment spe
© Copyright 2013 OAKWORKS® , Inc.This manual was originally drafted and approved in the English lan-guage.Printed in USAAll rights are reserved. No
17SPECIFICATIONSGuidance and manufacturer’s declaration - electromagnetic immunityThe chair is intended for use in the electromagnetic environment spe
18THIS PAGE IS INTENTIONALLY LEFT BLANK
19THIS PAGE IS INTENTIONALLY LEFT BLANK
20REVISION HISTORYREVISION HISTORYREVISION DAT EDESCRIPTIONA 08/08/2013 Word - New DocumentB 08/21/2013 Updated to Indesign Format; Updated specicat
Manual Part Number MMMNST0037-EN Revision level: DEnglish, Printed in USACONTACT INFORMATION:Oakworks® Inc.923 East Wellspring Road New Freedom,
TABLE OF CONTENTSProduct Use Description ... 1Important Safety
PRODUCT USE DESCRIPTION / IMPORTANT SAFETY INSTRUCTIONS1CAUTIONREAD AND SAVE THESE INSTRUCTIONSThe Back Rest and Leg Rest sections are not designed to
2IMPORTANT SAFETY INSTRUCTIONSThe arm rests are not designed to be used as patient restraints. Use appropriate patient restraints.The chair should not
3PRODUCT DESCRIPTION300 Series Procedure Chair For electrical specs, see Specifications section.STANDARD SPECIFICATIONSMotion 1 Powered 19”-35” (48-89
4The Procedure Chairs come completely assembled and ready to use. Plug the cord into a functioning outlet that is rated for the table. (see Grounding
5DIRECTIONS FOR USECAUTIONHAND CONTROL OPERATIONSDo not sit on the Fowler (Backrest) or Leg Rest sections. Do not leave the patient unat-tended. When
6DIRECTIONS FOR USECAUTIONFOOT CONTROL OPERATIONSDo not sit on the Fowler (Backrest) or Leg Rest sections. Do not leave the patient unat-tended. When
Comments to this Manuals